Key Takeaway

To check a 4-pin relay, start by setting your multimeter to the ohms setting. Identify the coil terminals, which are usually marked as 85 and 86. Connect the multimeter leads to these terminals. A reading between 50 and 200 ohms indicates the coil is intact.

Next, locate the common terminal, marked as 30, and the normally open terminal, marked as 87. Connect the multimeter leads to terminals 30 and 87. The reading should be infinite when the relay is inactive. Activate the relay and check again. A low resistance reading now indicates the relay is working properly.

Understanding Relay Terminal Markings

Relay terminals are often marked with specific designations that indicate their function. These markings are crucial for identifying the correct connections:

Coil Terminals: Typically marked as 85 and 86, these terminals are used to energize the relay coil.
Common Terminal (C): Marked as 30, this terminal is the common connection point for the relay contacts.
Normally Open (NO): Marked as 87, this terminal is connected to the common terminal when the relay is energized.
Normally Closed (NC): Marked as 87a, this terminal is connected to the common terminal when the relay is not energized.
Understanding these standard markings helps in quickly identifying the function of each terminal, making it easier to wire the relay correctly.

FAQ Image

Common Relay Terminal Configurations

Relays come in various configurations, each suited for specific applications and operational requirements. Understanding these configurations is crucial for newly joined engineers to select and wire the appropriate relay correctly.

SPST (Single Pole Single Throw) relays are the simplest type, featuring four terminals—two for the coil and two for the switch. When the relay is energized, the contacts close, allowing current to flow through the switch terminals. These relays are commonly used for basic on-off control applications, such as turning a device on or off with a single signal.

SPDT (Single Pole Double Throw) relays have five terminals: two for the coil, one common terminal (C), one normally open (NO), and one normally closed (NC). This configuration allows the relay to switch between two circuits. When the coil is energized, the common terminal connects to the normally open terminal, and when de-energized, it connects to the normally closed terminal. SPDT relays are versatile and used in applications requiring switching between two states, like in changeover circuits.

DPDT (Double Pole Double Throw) relays feature eight terminals. They can control two separate circuits, each with its own common, normally open, and normally closed contacts. This relay type is highly versatile, providing complex switching capabilities and often used in applications requiring multiple circuit control or reversing motor directions.

Familiarity with these common relay configurations helps in selecting the right relay for various applications, ensuring proper functionality and efficient wiring in your electrical systems. Understanding the specific terminal layout and operation of each type enables accurate and reliable relay integration into your projects.

Using a Multimeter to Identify Terminals

A multimeter is an invaluable tool for identifying relay terminals, especially when markings are unclear or absent. Knowing how to use it effectively can make the task straightforward and reliable.

First, set your multimeter to the resistance (ohms) setting. This allows you to measure the resistance between pairs of terminals. Identify the coil terminals by measuring the resistance between various pairs. The pair that shows a resistance reading typically between 50 to 200 ohms is the relay coil. This resistance indicates the coil is intact and capable of being energized.

Next, switch the multimeter to the continuity setting. This setting helps in identifying the contact terminals. With the multimeter set to continuity, test the remaining terminals. The common terminal (C) will show continuity with either the normally open (NO) or normally closed (NC) terminal, depending on whether the relay is energized or de-energized. Energize the relay by applying the appropriate voltage to the coil terminals and observe the changes in continuity to identify the NO and NC terminals.

Using a multimeter helps accurately identify each terminal, ensuring proper connections and reliable relay operation. This method is crucial for ensuring that your relay is wired correctly, thus maintaining the reliability and efficiency of your electrical systems.

Practical Examples and Diagrams

Practical examples and diagrams are invaluable for understanding relay terminal identification, making the concept clear and easy to apply. Let’s consider a Single Pole Double Throw (SPDT) relay, which is commonly used in various applications.

In an SPDT relay wiring diagram, the coil terminals are connected to pins 85 and 86. These terminals energize the relay when voltage is applied. The common terminal, often marked as pin 30, is the point that switches between the normally open (NO) and normally closed (NC) terminals.

The Normally Open (NO) terminal is pin 87. When the relay coil is energized, the common terminal connects to the NO terminal, allowing current to flow through. The Normally Closed (NC) terminal is pin 87a. In the de-energized state, the common terminal connects to the NC terminal, completing a different circuit path.

Visualizing these connections helps in comprehending the relay’s operation. For instance, in an automotive application, the SPDT relay can control a headlight circuit. When the relay is de-energized, the common terminal connects to the NC terminal, keeping the headlights off. When energized, the common terminal connects to the NO terminal, turning the headlights on.

Practical examples like this reinforce theoretical knowledge, making it easier to apply in real-world scenarios. Understanding and visualizing these connections ensures accurate and effective wiring, enhancing the reliability and functionality of your electrical systems.

Tips for Correct Identification

Accurately identifying relay terminals is crucial for ensuring reliable and functional circuits. Here are several practical tips to help you achieve this:

Refer to the Datasheet: Always start by checking the relay’s datasheet. The datasheet provides terminal designations and wiring diagrams specific to the relay model, helping you understand the correct connections.

Label the Terminals: If the relay’s markings are unclear or worn off, label the terminals after identifying them. Use a permanent marker or adhesive labels to avoid confusion during installation and future maintenance.

Use Reliable Tools: Ensure your multimeter is calibrated and in good working condition. Accurate measurements are essential for correctly identifying coil and contact terminals.

Check for Manufacturer Standards: Different manufacturers might have slightly varied terminal markings. Always confirm the standard used by referring to the manufacturer’s documentation or support resources.

By following these tips, you can accurately identify and connect relay terminals, which enhances the reliability and functionality of your circuits. Proper identification helps prevent wiring errors, reduces troubleshooting time, and ensures that your electrical systems operate smoothly. As a newly joined engineer, mastering these tips will contribute significantly to your proficiency and confidence in handling relays and other electrical components.

Conclusion

Accurately identifying relay terminals is crucial for ensuring the correct operation of electrical systems. By understanding terminal markings, common configurations, and using tools like multimeters, you can confidently identify and connect relay terminals. Practical examples and following helpful tips further ensure accuracy. Mastering this skill is essential for any engineer, enhancing your ability to design and maintain reliable electrical circuits.