How To Check Relay With Multimeter | IndMALL Automation
+91 79955 44066 sales@indmall.in

How To Check Relay With Multimeter

Key Takeaway

To check a relay with a multimeter, follow these simple steps:

Set the Multimeter: Turn your multimeter to the continuity test mode, indicated by a sound wave symbol or simply marked as “continuity.”
Test the Coil: Place the multimeter’s probes on the relay’s coil terminals.
Listen for the Beep: If you hear a continuous beep, it means the coil is intact and the relay should be functioning properly. If there’s no beep, the coil may be broken, suggesting the relay is faulty.
This quick check helps you determine whether your relay is in good condition or needs replacement

Preparing for Relay Testing

Before testing a relay with a multimeter, gather necessary tools: a digital multimeter and the relay in question. Ensure the relay is disconnected from the circuit to avoid electrical hazards. Set your workspace on a non-conductive surface and have the relay’s datasheet handy for reference. Familiarize yourself with the relay’s pin configuration, as this will guide your testing process. Safety is paramount; wear insulated gloves and use tools with insulated handles to prevent accidental shocks.

FAQ Image

Checking Coil Resistance

To check the coil resistance of a relay, first, set your digital multimeter to the resistance (ohms) setting. This will allow you to measure the electrical resistance within the relay’s coil. Next, identify the relay’s coil terminals. These terminals are typically marked on the relay housing or can be found in the relay’s datasheet. Accurate identification of these terminals is crucial for proper measurement.

Place the multimeter probes on the identified coil terminals. Ensure that the probes are making firm contact to avoid inaccurate readings. Observe the resistance value displayed on the multimeter. A functional relay coil will usually show a resistance ranging from a few ohms to several hundred ohms, depending on the relay’s design and specifications.

If the multimeter displays a resistance of zero ohms, this indicates a short circuit within the coil, rendering the relay non-functional. On the other hand, if the multimeter reads infinite resistance, it means the coil is open and no continuity exists, which also necessitates relay replacement. Regularly checking the coil resistance helps in identifying issues early, ensuring the relay operates efficiently and preventing potential circuit failures.

Testing Relay Contacts

Testing relay contacts is essential to ensure they function correctly. Begin by setting your multimeter to the continuity setting. Continuity testing checks whether an electrical path is established, indicated by a beep sound from the multimeter.

First, identify the common terminal (COM), normally open (NO), and normally closed (NC) contacts on the relay. Place one probe on the common terminal and the other on the NC terminal. The multimeter should beep, indicating continuity, as the NC contact is closed when the relay is de-energized.

Next, move the probe from the NC terminal to the NO terminal. There should be no beep, indicating no continuity, as the NO contact is open when the relay is de-energized.

To test the relay under operating conditions, energize the relay by applying the rated voltage to the coil. This can be done using a power supply or a battery of the appropriate voltage. With the relay energized, place one probe on the common terminal and the other on the NO terminal. The multimeter should now beep, indicating continuity, as the NO contact is closed when the relay is energized.

Lastly, move the probe back to the NC terminal. There should be no beep, indicating no continuity, as the NC contact is open when the relay is energized. This procedure confirms that the relay switches correctly between its NO and NC contacts when activated.

Interpreting Multimeter Readings

Interpreting multimeter readings accurately is crucial for diagnosing the functionality of a relay. When checking coil resistance, the measured value should closely match the specifications provided in the relay’s datasheet. For instance, if the datasheet states a coil resistance of 120 ohms, a significant deviation from this value could indicate a problem. A reading much higher than specified suggests an open coil, while a much lower reading indicates a shorted coil.

For continuity tests, you should expect specific results depending on the relay’s state. When the relay is de-energized, there should be continuity between the common terminal and the normally closed (NC) contact, which will be indicated by a beep from the multimeter. Conversely, there should be no continuity between the common terminal and the normally open (NO) contact.

When the relay is energized, these conditions should reverse. The multimeter should show continuity between the common terminal and the NO contact, and no continuity between the common terminal and the NC contact. Any anomalies in these readings could indicate issues such as contact welding, where contacts remain stuck together, corrosion, or mechanical failure within the relay.

Accurate interpretation of these readings helps identify whether a relay is functioning correctly or needs replacement, ensuring the reliability and safety of the electrical system it controls.

Troubleshooting Common Issues

Troubleshooting common issues during relay testing involves identifying problems such as open coils, welded contacts, or inconsistent continuity. If the coil resistance is significantly higher than specified or shows an open circuit (infinite resistance), it indicates that the coil is damaged and the relay needs replacement. This situation arises due to coil burnouts or wire breakages within the coil.

Contact issues often manifest as unexpected continuity results. For instance, if the normally closed (NC) contact does not show continuity when the relay is de-energized, or the normally open (NO) contact does not show continuity when energized, this suggests contact problems. Such issues may be due to welding, where contacts are fused together from excessive current, or due to corrosion and dirt accumulation.

Inspect the relay for visible signs of wear or damage. Cleaning the contacts with a contact cleaner can resolve minor issues caused by dirt or oxidation. However, if the relay still does not function correctly after cleaning, replacing it is the safest and most effective solution. Regular maintenance and timely replacement of faulty relays ensure the reliability and safety of the electrical systems they control, preventing potential failures and downtime.

Conclusion

Using a multimeter to check a relay’s functionality is a straightforward yet essential skill for ensuring reliable operation in electrical systems. By systematically testing coil resistance and contact continuity, you can diagnose and address common relay issues, ensuring your circuits run smoothly. Regular testing and maintenance of relays not only prevent unexpected failures but also extend the lifespan of your electrical components, ensuring safety and efficiency in various applications.